MPL1510

DIODE PUMPED PICOSECOND PASSIVELY Q-SWITCHED LASER

MPL1510 series DPSS passively Q-switched picosecond lasers deliver high peak powers > 2 MW at 100 Hz repetition rate. Short laser cavity is fixed on thermo-stabilized and controlled baseplate which gives extremely stable output parameters performance. Small footprint is welcome point for integration into OEM lasers. Pulse duration of < 500 ps, high pulse energy more than 1 mJ, variable repetition rate from 1 Hz to 100 Hz covers many applications like pollution monitoring, DNA analysis, supercontinuum generation and many others.

Due to short pulse duration and high pulse energy laser delivers high peak power which is up to 2 MW. Optional conversion to green (532 nm) and ultraviolet (355 nm, 266 nm) is also available.

FeaturesApplications
  • More than 1 mJ pulse energy at 1064 nm
  • Short pulse duration < 500 ps
  • Variable up to 100 Hz repetition rate
  • Passively Q-Switched
  • Average power 100 mW
  • High peak power > 2 MW
  • Guaranteed > 3 Gshot lifetime
  • Other wavelengths (e.g. 532 nm, 355 nm, 266 nm) are available
  • Medical
  • Surface disinfection 
  • Laser induced breakdown spectroscopy (LIBS)
  • Time resolved fluorescence measurements
  • DNA analysis
  • Pollution monitoring
  • Remote sensing
  • Supercontinuum generation
  • Ignition of gas mixtures

 

Model 
MPL1510   
Pulse energy:
    at 1064 nm> 1 mJ
    at 532 nm> 0.5 mJ
    at 355 nm> 0.25 mJ
    at 266 nm> 0.15 mJ
Typical pulse duration< 450 ps 2)
Pulse to pulse energy stability (RMS):
    at 1064 nm:< 1 % 3)
    at 532 nm:< 2.5 % 3)
    at 355 nm:< 3.5 % 3)
    at 266 nm:< 5.0 % 3)
Power drift± 3.0 %  4)
Pulse repetition rate 5)1 – 100 Hz
Beam profileClose to Gaussian
Beam divergence 6)< 5 mrad
PolarizationLinear, horizontal at 1064 nm
Spectral LinewidthSLM
Beam pointing stability 7)< 50 µrad
Typical beam diameter  8)2 mm
Jitter~ 2 µs RMS 9)
Dimensions
Laser head (W×L×H)83 × 157 × 41.5 mm
Controller unit (W×L×H)75 × 200 × 70 mm (OEM version)
Power adapter (W×L×H)119 × 179 × 30 mm (OEM version)
Operating requirements
Cooling requirementsAir cooled
Ambient temperature15 – 30 ºC
Relative humidity (non-condensing)10 – 80 %
Mains voltage90-230 VAC, single phase, 47-63 Hz 10)
Power consumption< 10 W

1. Due to continuous improvements all specifications are subject to change. Unless stated otherwise all specifications are measured at 1064 nm.
2. FWHM level at 1064 nm. Shorter pulse duration (< 350 ps) is available by request. Please inquire for detailed specifications.
3. Averaged from 60 seconds time interval.
4. Over 8-hours period after max 5 minutes of warm-up when ambient temperature variation is less than ±2 °C.
5. Factory-set pulse repetition rate is fixed at max repetition rate. Higher repetition rates are available, please inquire for details.
6. Full angle measured at the 1/e2 level.
7. RMS value measured from 1000 shots.
8. Beam diameter is measured 20 cm from laser output at the 1/e2 level.
9. In respect to Q-switch triggering rising edge pulse.
10 Laser can be powered from an appropriate 12 VDC power source. Inquire for details.

 

Laser head dimensions:


Typical beam intensity profile (20 cm from laser output) of MPL1510 series lasers:

BROCHURE - QS Lasers solutions for OEMs and Industry. qslasers.com PICOSECOND LASERS, Passively Q-switched, MPL1310-FC, MPL1510-FC, Actively Q-switched, LASER ELECTRONICS and Laser diode drivers, LDTC100A. Temperature controller with crystal oven, DCCO Series, SPECTROSCOPY SYSTEMS. Raman Microscopy systems, NS200 Series and News, About us.

BROCHURE

MPL1510 Request